Get Adobe Flash player
Login
To prevent automated spam submissions leave this field empty.
Orthopedic Surgery Devices
General Surgery Devices
Home | Reconstruction- Hip | Femoral Revision Systems

ReCap Femoral Resurfacing System

Company Name: 
Biomet
Model No.: 
NA
Regulatory Approval: 
FDA
Recap.JPG

 Replacement of the diseased surface of the femoral head while simultaneously restoring the normal anatomy and biomechanical function. The ReCap® Femoral Resurfacing System replaces the diseased surface of the femoral head and is designed to restore the normal anatomy and biomechanical function of the hip joint.

The major advantage of the ReCap® Femoral Resurfacing System is its conservative nature. By avoiding medullary canal intrusion, it preserves valuable femoral bone stock, making it a bone-preserving alternative to total hip arthroplasty. A 2006 study published by Girard, J. et al. in the Journal of Bone and Joint Surgery (British) concluded that a group of young patients with femoral hemi-resurfacing were able to maintain a higher average activity level versus a similar group of patients who received a total hip arthroplasty1. Results suggest that improved resurfacing results may be attributed to the following:

  • Reduced pain and quicker recovery time from hemi-resurfacing surgery
  • Precision fitting of the hemi-resurfacing component to the size of the acetabulum


Key Features

  • Traditional design with a cylindrical stem that extends beyond the shell
  • Precise congruity between the prosthesis and the acetabular cartilage
  • As-cast, high carbon/high carbide, CoCr substrate for wear resistance
  • Highly polished bearing surface helps minimize wear of acetabulum
  • Large range of femoral resurfacing heads in one millimeter increments to help produce a precise anatomical fit
  • Press-fit and cemented resurfacing heads available in sizes 38mm-60mm
  • Accurate and reproducible ReCap® instrumentation to simplify the surgical technique and reduce operating time

New ReCap® KS Alignment Device: An Evolution in Resurfacing

Femoral component positioning is vital to the success of hip resurfacing. Current devices on the market for guide pin placement often require a considerable amount of visualization and user experience to allow for accurate guide pin placement. The new ReCap® KS Alignment Device has demonstrated:

  • Reproducible and reliable implant positioning
  • Consistent placement of the ReCap® femoral implant within acceptable limits pre-determined by computer aided navigation during extensive cadaver testing4
  • No significant difference in implant positioning between an inexperienced surgeon that used the alignment device to implant a ReCap® femoral component and an experienced surgeon that used navigation 

Key Benefits

  • Large diameter head lowers potential for risk of dislocation6
  • Minimal bone resection preserves bone for the future
  • No polyethylene articulating surface greatly reduces risk of osteolysis
  • Minimizes risk of leg length discrepancies by more accurately reproducing the patient's original anatomy